Energimærkeordningen (EMO)

Tabeloversigt ?
ZoneEntry
PDFReportData
BuildingUnit
PDFReportDataBuilding
Boiler
Ventilation
ResultFigures
SolarHeatingPlant
DistrictHeatWithExchanger
Window
EnergyLabel
ProposalGroup
RoomHeating
Utility
Lighting
OtherSourceTemperatures
PDFReportDataProposalGroup
Comments
FuelConsumption
Building
HotWater
LoggedConsumption
Proposal
ReportedConsumption
Address
Be06KeyFigures
DirectDistrictHeat
HotWaterTank
SolarCell
ZoneStatus
BbrBuilding
FuelAmount
ReportConfiguration
Stove
AdjustedLoggedConsumption
AdjustedReportedConsumption
BuildingResult
Cooling
EnergyFrame2010
EnergyFrame2015
EnergyFrame2018
EnergyFrame2020
FuelAmountHeatingConsumption
FuelAmountOtherElectricalConsumption
FuelAmountProduction
HeatPump
LowEnergyFrame
ProposalGroupResult
ReportedConsumptionInPeriod
Shade
SunBurdenedRoom
Text
WindMill
ZoneResultResultForAllProfitableProposals
ZoneResultResultForAllProposals
ZoneResultStatus
Be15KeyFigures
Be18KeyFigures
BuildingPart
Company
FuelEconomy
HeatDistributionPipe
HotWaterCirculationPump
HotWaterGasHeater
HotWaterPipe
InputData
LinearThermalTransmittance
Price
ZoneResult
Be10KeyFigures
EnergyLabelType
Fuel
FuelSaving
HeatDistributionPump
HotWaterChargingPump
InternalHeatContribution
RenovationClass1
RenovationClass2
ReportedConsumptionAdjustedToStandardYear
SecondaryElectricHeat
SimpleAddress
Apartment
AutoLabelBuilding
Bbr
BlockHeat
Consultant
DWHBuildingUnitValue
ElectricHeat
FuelPrice
HeatDistributionSystem
HotWaterElectricHeater
InputDataForAutoLabel
LabelResult
TotalCo2Emissions
TotalFuelEconomy
VentilationDuct
AutomaticControl
CalculatedBe06Result
CalculatedBe10Result
CalculatedBe15Result
CalculatedBe18Result
CalculatedSolarCellUtilization
CalculationSoftware
DWHBuildingUnit
DWHBuildingUnitAttribute
EnergyLabelSoftware
HotWaterConsumption
Image
OtherElectricConsumption
ProposalGroupReference
ProposalReference
Submitter
BuildingResultStatus
DWHBuildingUnitType
EnergyLabelXml
LabelResultStatus
ResultData
ResultForAllProfitableProposals
ResultForAllProposals
FuelExchanges
Tabel

Ventilation


Beskrivelse ?

Tabellen beskriver ventilation for bygningen. Her indgår information om, areal relativ driftstid, naturlig ventialtion om vinteren, naturlig ventilation om sommeren, naturlig ventilation sommeren uden for brugstid, mekanisk ventilation om vinteren, mekanisk ventilation om sommeren, mekanisk ventilation om natten om sommeren, infiltration, temperaturvirkningsgrad, indblæsningstemperatur, SEL-værdi, elvarmeflader, installionsår, inspektionsdato, serviceeftersynsaftale og effekt af anlægget.

Størrelse (Antal rækker) ?

1068664

Indhold (Kolonner/variable) ?

Navn Indhold
VentilationId Identifikator for Ventilation-entry
Area Areal for ventilationen (kvm)
UsageFactor Den relative driftstid af ventilationssystemet i forhold til bygningens brugstid (Enhedsløs faktor).
NaturalVentilationWinter Naturlig ventilation om vinteren i brugstiden (l/s kvm).
NaturalVentilationSummer Naturlig ventilation om sommeren i brugstiden (l/s kvm).
NaturalVentilationSummerOutsideUsageHours Naturlig ventilation om sommeren uden for brugstiden (l/s kvm).
MechanicalVentilationWinter Mekanisk ventilation om vinteren (l/s kvm)
MechanicalVentilationSummer Mekanisk ventilation om sommeren (l/s kvm)
MechanicalVentilationSummerOutsideUsageHours Mekanisk ventilation om natten om sommeren (l/s kvm)
InfiltrationOutsideUsageHours Infiltration er utilsigtet indføring af udeluft gennem revner eller åbning af døre/vinduer. I rum med naturlig eller mekanisk udsugning er det en del af ventilationen, mens det i balanceret mekanisk ventilation er oveni (l/s kvm).
TemperatureEfficiency Varmegenvindingens temperaturvirkningsgrad. Angives for veksleren alene uden bidrag fra andre kilder, fx motorvarme fra ventilatorerne (%).
InjectionTemperature I ventilationsanlæg med både reguleret varmegenvinder og varmeflade antages indblæsningstemperaturen at være 18 °C. Uden regulering sættes et minus foran temperaturen, og uden varmeflade og ureguleret varmegenvinder er temperaturen 0 °C (Celsius).
SpecialPowerUsage Det specifikke elforbrug til lufttransport (SEL-værdi) er elforbruget til ventilatorerne inklusive reguleringsudstyr og lignende divideret med den transporterede udeluftvolumenstrøm (kJ/kubikmeter).
HasHeatCoils Hvis der er elvarmeflade i ventilationsanlægget, skrives der 1 i feltet og ellers angives værdien til 0.
ConstructionYear Det årstal anlægget blev installeret (årstal).
InspectionDate Dato for seneste eftersyn
RegularInspection Er der indgået aftale om løbende serviceeftersyn af ventilationsanlægget (ja/nej).
NominalEffect Effekt af anlægget (kW).